Key Fire Hose
FLAME OUT MSHA Single Jacket
Types:
Fire Protection
Vendor: Key Fire Hose
Application:
Key Fire “Flame Out” MSHA approved single jacket fire hose designed specifically for underground mine applications.- 600 Pound Test Heavy Duty Lightweight
- MSHA approved
- Extruded Tube File #18-FHA080002
- 1-1/2" & 2"
- 1 year warranty
- Abrasion Resistance
- Cold Resistance
- Heat Resistance
- Self Extinguishing
- Flame Resistant
PROUDLY MADE IN THE USA
Quality:
The fire hose assembly supplied under this specification shall be constructed with superior quality materials. NFPA 1961 standards shall be observed in production of the assembly, in order to ensure its quality and durability. Hose furnished under these specifications will have a potential service life warranty of one year; barring mistreatment that would render it unfit for service. Upon delivery, the hose shall be free from defects in workmanship and materials. Any defective hose will be replaced at no charge.Jacket Construction
The single jacket will be woven evenly and be free of defects, including knots lumps or unsightly disfigurations that could jeopardize the integrity of the hose assembly. The warp yarn shall consist of staple polyester yarn. The use of filament or entangled yarn is expressly forbidden due to the lack of inherent abrasion resistance. The filler yarns shall be constructed of high strength, low elongation, filament polyester to reduce weight and increase flexibility.Lining
The lining shall be a single-ply extruded tube of synthetic polyurethane based material to resist ozone. This special MSHA approved material shall adhere to the jacket by vulcanization process to prevent delamination and/or hydrolysis. The finished product will meet and exceed all MSHA specifications and be listed with File #18-FHA080002. This product is designed with self-extinguishing characteristics meeting MSHA standards. Neoprene or other rubber products that give off chlorine or other toxic gases shall not be acceptable.Hydrostatic UL Testing
Service test pressure shall pass 300 PSI. Acceptance test pressure shall pass 600 PSI. Curve and straight burst testing shall 900 PSI.All testing shall be in accordance with NFPA1962 and UL-19 procedures.Finished Hose
Printed letters with the words "Flame-resistant USMSHA 18-FHA080001" must be premanently marked on the product with letters at least 1/4" high and at intervals not exceeding 3 feet. NFPA approved markings shall be stenciled 4 feet from each end.Couplings
Internal expansion ring threaded couplings or as required by purchaser.** Customers are advised special diameters or construction characteristics may be produced
by special request. For more information please contact your JGB Sales Representative.
Weights and Measures
Size | Part No. | Service Test | Proof Test | Burst Test | Bowl Size |
Weight/50' | Request Quote |
1 1/2" | SP15-MSHA | 300 psi | 600 psi | 900 psi | 1 3/4" | 12 lbs. | Request Quote |
2" | SP20-MSHA | 300 psi | 600 psi | 900 psi | 2 1/4" | 17 lbs. | Request Quote |
2 1/2" | SP25-MSHA | 300 psi | 600 psi | 900 psi | 2 3/4" | 23 lbs. | Request Quote |
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov |