New Age
Silbraid Medical Grade Reinforced Silicone Hose
Types:
Special Application
Vendor: New Age
Application:
Silbrade Medical a peroxide-cured product.Not recommended for implantable or in-body use.
Tube:
Silicone Tubing
Reinforcement:
Open mesh polyester braiding
Cover:
Silicone elastomer
Temperature:
Brittle -80°F
Maximum operating temperature 350°F
Packaging:
Individual, non-sterile, heat-sealed polybags
Couplings:
Thermobarb® barbed fittings, Oetiker® ear type clamps, Kwik Clamp™ nylon double bond hose clamps, Worm gear clamps
Category:
Medical Grade
Colors:
Translucent
Options:
Custom Services: Cut, Size, Overbraid and More...
- Open mesh polyester braiding incorporated within the walls of silicone tubing
- Silicone elastomer meets USP Class VI requirements
- Translucent natural color for visual contact with the flow
- Able to resist extreme temperature variation: -80°F to 350°F
- Odorless, tasteless, and inert
- All ingredients are non-toxic and FDA-sanctioned for use with food contact surfaces
- Manufactured under good manufacturing procedures in a controlled environment
NotesSILBRADE MEDICAL’s construction consists of a core of silicone elastomer, an open polyester braid reinforcing layer, and a cover layer of silicone elastomer. Good manufacturing procedures, including lot traceability, are applicable to all Class VI ingredients. SILBRADE MEDICAL is a peroxide-cured product. The hose’s smooth bore, coupled with its resistance to allow material to adhere to the tube wall, facilitates easy cleaning and system purging. SILBRADE MEDICAL is not recommended for implantable or in-body uses. SILBRADE MEDICAL may be low pressure sterilized in-line or autoclaved up to 250°F in a normal autoclaving cycle. If exposed to repeated steam sterilization or long-term high temperature or pressure, silicone will eventually relax and become gummy. It should then be replaced. Care is recommended in the selection and application of fittings and clamps, as sharp barbed fittings or unlined clamps could tear into the hose wall and possibly cause a failure, especially at elevated pressures. Peroxide-cured SILBRADE MEDICAL hose is supplied in individual, non-sterile, heat-sealed polybags and should be sterilized prior to use. A platinum-cured, braid-reinforced medical grade silicone hose is available. Minimum quantities apply; call for price and delivery. |
|
Physical Properties ** |
|
Hardness, Shore A ±5 – Core Hardness, Shore A ±5 – Cover Tensile Strength, psi Elongation at Break, % Brittle Temperature, °F Maximum Operating Temperature, °F |
70 60 1000 350 -80 350 |
** Values listed are typical for the material used in manufacture, except where noted, and are meant only as a guide to aid in design. Field testing should be performed to find the actual values for your application. |
PART NO. |
ID (IN.) |
OD (IN.) |
WALL (IN.) |
WORKING PSI AT 70°F |
BURST PSI AT 70°F* |
LBS. PER 100 FT. |
Request a Quote |
291 0257 | 3/16 | .447 | .130 | 216 | 648 | 7 | Request Quote |
291 0334 | 1/4 | .520 | .135 | 208 | 624 | 9 | Request Quote |
291 0411 | 5/16 | .592 | .140 | 183 | 549 | 11 | Request Quote |
291 0488 | 3/8 | .655 | .140 | 166 | 498 | 13 | Request Quote |
291 0565 | 1/2 | .800 | .150 | 141 | 423 | 17 | Request Quote |
291 0719 | 3/4 | 1.100 | .175 | 91 | 273 | 28 | Request Quote |
291 0873 | 1 | 1.380 | .190 | 75 | 225 | 36 | Request Quote |
Example: 25 ft. of 3/16" I.D. hose is part number 291 0257-25.
*Burst pressures can be expected to decrease by at least 20% for each 200°F increase up to 350°F.
BOLD indicates the critical dimension for fittings application.
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov |