REQUEST A QUOTE
Download JGBHose from Apple App Store Download JGBHose from Google Play

Parker Industrial
Chemical Transfer Hose - Series 3100

Chemical Transfer Hose - Series 3100

Types:
Petroleum Hose     Sub Type: Petroleum Petro Transfer Hose


Vendor: Parker Industrial

Application:

Chemicals, inks, paints, plant processing, rail cars, tank trucks

NOTE:  Not for dry material service.

Parker composite petrochemical hose is economical, flexible, light weight, durable and resistant to abrasion, kinking and vibration. Assemblies manufactured per customer requirement; hydro-statically tested to 150% of the rated working pressure.

Couplings:

Contact JGB for proper fitting recommendation and coupling procedure.

Colors:

Black with gold stripe

Inner Wire: Polypropylene-coated steel (P)
Inner Liner: Polypropylene fabric
Hose Wall: Multiple layers of fabric/film/tubes
Cover: Black PVC coated polyester
Outer Wire: Galvanized steel (G)
Temp. Range: -40°F to +212°F (-40°C to +100°C)
Brand Method: Black text on gold stripe
Brand Example: PARKER SERIES 3100 CHEMICAL TRANSFER HOSE 250 PSI MAX WP MADE IN USA
Design Factor: 4:1
Industry Standards: None applicable
Vacuum: Full
Standard Wire: (Polypropylene-coated steel inner) and G (Galvanized) outer

Part No. ID
(in)
ID
(mm)
Approx Wt
(lbs/ft)
Min Bend
Rad
(in)
Max Rec
WP
(psi)
Max Lg
(ft)
Request Quote
3100PG-1000 1 25.4 0.8 5.0 250 75 Request Quote
3100PG-1500 1-1/2 38.1 1.0 6.0 250 75 Request Quote
3100PG-2000 2 50.8 1.2 6.5 250 75 Request Quote
3100PG-2500 2-1/2 63.5 1.6 8.0 250 75 Request Quote
3100PG-3000 3 76.2 2.0 9.5 250 70 Request Quote
3100PG-4000 4-1/2 101.6 4.4 16.0 250 70 Request Quote
3100PG-6000 6 152.4 7.0 20.0 250 65 Request Quote
3100PG-8000 8 203.2 10.0 29.0 250 65 Request Quote
Alternative P/N Example:
3100PS-4000 (Polypropylene coated inner; Stainless outer)

WARNING!

  • It is the responsibility of the user to determine if the hose is suitable for the application. Elevated temperatures can change the chemical resistance ratings. Many chemicals will become more aggressive as temperatures increase, reducing the ability of hose materials to withstand them. Contact JGB for chemical compatibility data at elevated temperatures. Contact JGB for additional chemical compatibility information. If no data exists, users are required to perform compatibility testing at the desired temperature.
   WARNING: Cancer and
   Reproductive Harm -
   www.P65Warnings.ca.gov