Aeroquip - 2807 PTFE Hose

2807 PTFE Hose

Vendor: Aeroquip

Category: Special Application


Application:

SAE 100R14A

Hot air, steam, compressor discharge and most chemical applications. Not recommended for steam-cold water cycling.

Tube:

Extruded PTFE tube

Cover:

Stainless steel single wire braid

Temperature:

–100°F to +500°F (–73°C to +260°C).

Couplings:

Contact JGB for proper fitting recommendation and coupling procedure.

Part Number Hose I.D. Hose O.D. Maximum
Operating
Pressure
Minimum
Burst
Pressure
Minimum
Bend
Radius
Vacuum
Service
Weight
of Hose
Request a Quote
mm in mm in bar psi bar psi mm in kPa in/Hg Kg/m lbs/ft
2807-3 3,6 0.14 6,4 0.25 210,0 3000 840,0 12000 38,1 1.50 94,8 28 0,06 0.04 Request Quote
2807-4 4,8 0.19 7,6 0.30 210,0 3000 840,0 12000 50,8 2.00 94,8 28 0,09 0.06 Request Quote
2807-5 6,6 0.26 9,4 0.37 210,0 3000 840,0 12000 76,2 3.00 94,8 28 0,12 0.08 Request Quote
2807-6 8,1 0.32 10,9 0.43 175,0 2500 700,0 10000 101,6 4.00 94,8‡ 28‡ 0,15 0.10 Request Quote
2807-8 10,7 0.42 13,7 0.54 140,0 2000 560,0 8000 133,4 5.25 94,8‡ 28‡ 0,18 0.12 Request Quote
2807-10 13,0 0.51 16,0 0.63 105,0 1500 420,0 6000 165,1 6.50 94,8‡ 28‡ 0,24 0.16 Request Quote
2807-12 16,3 0.64 19,3 0.76 84,0 1200 335,0 4800 196,9 7.75 94,8‡ 28‡ 0,27 0.18 Request Quote
2807-16 22,4 0.88 26,2 1.03 70,0 1000 280,0 4000 228,6 9.00 40,6‡ 12‡ 0,39 0.26 Request Quote
2807-20 28,4 1.12 32,8 1.29 43,0 625 175,0 2500 406,4 16.00 40,6‡ 12‡ 0,51 0.34 Request Quote

‡ Maximum negative pressure for -06 and larger are
suitable for hose which has suffered no external damage or
kinking. If greater negative pressures are required for -06 and
larger hoses, the use of an internal support coil is recommended.
Use of an internal support coil in -06 and larger PTFE hose is
recommended for tube support where extended or continuous
service at high temperature together with low or negative pressure is expected.

   WARNING: Cancer and
   Reproductive Harm -
   www.P65Warnings.ca.gov