JGB Private Brand - Eagle Water Transfer PU for Produced-Water
Vendor: JGB Private Brand
Category: Water Hose
Sub Type: Water Suction & Discharge Hose
Application:
For Frac Water Transfer Chemical; Fluid Transfer; Produced Water Transfer; Acid Transfer.
Eagle Water Transfer PU Frac Water Hose is made from extruded thermoplastic polyether based polyurethane(TPU) with excellent wear & tear properties, with reinforcement made from circular woven filament polyester yarn. The "extrusion through-the-weave" production method gives a very strong bonding between cover and lining as well as firmly encapsulating the woven polyester. Our PU Frac Water Hose offers high resistance against commonly used chemicals and has excellent resistance to UV radiation, hydrolysis and fungus degradation. The abrasion resistance of the TPU is one of the highest available, making the hose ideal for use in the extremely abrasive environment in open pit mines. The outer cover has been designed with extra thickness in order to add wear & tear material. This extends the useful lifespan of the hose, by offering extra abrasion resistance for rugged terrain and extreme conditions.
Tube:
TPU (Extrusion through-the-weave)
Reinforcement:
100% high tenacity Polyester Filament
Cover:
TPU (Extrusion through-the-weave)
Temperature:
-50°C to 80°C (-58°F to +178°F)
Couplings:
- Powder Coated
- 316 Stainless Steel
- PTFE Coated
Lengths:
100m (330ft), 200m(660ft), 300m(990ft), 400m(1320ft)
Features:
- Age Resistance
- Abrasion Resistance
- Acid Resistance
- Chemical Resistance
Technical Specification:
I.D. | Wall Thickness | Working Pressure | Bursting Pressure | Weight approx. | Request Quote |
inch | approx. inch | psi | psi | lbs/ft | |
4" | 0.138 | ≥250 | ≥750 | 0.94 | Request Quote |
6" | 0.150 | ≥250 | ≥750 | 1.41 | Request Quote |
8" | 0.177 | ≥300 | ≥900 | 2.28 | Request Quote |
10" | 0.197 | ≥300 | ≥900 | 3.75 | Request Quote |
12" | 0.228 | ≥200 | ≥600 | 4.30 | Request Quote |
14" | 0.205 | ≥150 | ≥450 | 4.96 | Request Quote |
16" | 0.205 | ≥150 | ≥450 | 5.10 | Request Quote |
*AII above technical parameters are only for reference, details please confirm with JGB
Nipple Chemical Test:
Test Item | Concentration % | Temperature approx°F | Endurance |
Nitric Acid | 10 | 75.2 | ≥1 year |
Phosphoric Acid | <5 | <212 | ≥1 year |
Calcium Chloride | 10 | 75.2 | ≥1 year |
Ammonium Hydroxide | 30 | 75.2 | ≥1 year |
Sodium Carbonate | 10 | 212 | ≥1 year |
Lead Sulfate | 30 | 75.2 | ≥1 year |
Ammonium Phosphate | Any | 75.2 | ≥1 year |
Ammonium Sulfate | Any | 75.2 | ≥1 year |
*AII above technical parameters are only for reference, details please confirm with JGB
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov |